Features
- 4-way load
- Emergency switch
- Over current protection, short circuit protection
- Current Detection
- High output power
- Small size and light weight
Main Technical Characteristics
Input | Bias voltage | DC18V~DC36V (With reverse connection protection) |
Bias current | ≤100mA | |
Output | Input power | 28Vd.c. |
Rated current | 35A per way | |
Output leakage current | <10μA | |
Voltage drop | ≤0.14Vd.c. | |
Control | Bus control or emergency control | |
Other parameters | Current sampling error | ±4% (normal temp.), ±8% (all temp. range) |
Communication Interface | CAN2.0B, extended frame, communication rate 250kbps | |
Protective function | Over current, short circuit, parameters settable | |
Insulation resistance | 500Vd.c., >100MΩ |
Environmental parameters
Item | Min | Max | Unit |
Operating temperature | -40 | 70 | °C |
Storage temperature | -55 | 85 | °C |
Shock | 294, 11 | (m/s2), ms | |
Vibration (high frequency) | 12.2, 10~2000 | (m/s2)2, Hz |
Working principle diagram and application instruction | Dimension |
Note: The tolerance of dimension is according to GB/T1804-m if not mentioned. |
Order mark
4WAZMK | – | 1 | Z |
Main code | Design number | Customization sign |
Note: If there is need to customize the bus communication protocol, you can sign a special technical agreement in which the order mark is determined.