Environmental Characteristics
No. | Parameter | Environmental Specification | |
1 | Quality Grade | Ⓙ | |
2 | Temperature Range | (℃) | -40~+100 |
3 | Relative Humidity | (40±2) ℃, 95% | |
4 | Low Pressure | (kPa) | 0.67 |
5 | Sinusoidal Vibration | (Hz) | 10~2000 |
(m/s2) | 100 | ||
7 | Shock | (m/s2) | 200 |
8 | Acceleration | (m/s2) | 300 |
Main Characteristics
Current and Number of Contacts | 5A, 94 groups
20A, 4 groups 50A, 4 groups Gas path, 1 group |
Dielectric withstanding voltage (V.r.m.s) (50Hz) | Normal | ≥1000 | |
Low pressure | ≥200 | ||||
Contact voltage (V d.c.) | 60 or 115 V a.c. | Weight(g) | Plug≤600
Receptacle≤400 |
||
Insertion torque (N.m) | ≤3 | Separation force(N) | ≤150 | ||
Contact Resistance (Ω) | Initial | ≤0.005 | Connection | Pins and jacks | |
After Life | ≤0.01 | Life Time (Cycles) |
Mechanical: 2×102 Electric explosion: 30 |
||
Insulation Resistance (MΩ)
(500 Vd.c.) |
Normal | ≥100 | Dimension (mm) | Plug: 142×100×50 | |
High Temp./Humidity | ≥50 | Receptacle: 80×115×60 |
Dimension
Plug | Receptacle |
Order mark
Example: G—103/Ⓙ
G | — | 103 | / | Ⓙ |
Product mark | Number of contacts, groups and positioning parts | Quality grade |
Standard: Q/RY.JO121-1991